The flame sensor is a single metal rod that sits in the burner flame and proves the furnace actually lit. It works by flame rectification: the flame conducts a tiny current — measured in microamps — back to the control board. If that current stops, the board shuts the gas valve within seconds, because it has no other way to know whether gas is burning or simply pouring into your house.
68 flame sensors in stock, ready for same-day pickup at our Coquitlam warehouse or shipped worldwide.
Signs your flame sensor may have failed
- Furnace lights, runs for 3–7 seconds, then shuts down and tries again
- Several ignition attempts, then a hard lockout
- Control board flashes a flame-sense or flame-failure code
- Problem is worse in the morning or after the furnace has sat idle
Not sure which part you need? Call 1-778-759-9864 with your furnace model number and we will confirm it before you order.
Shop flame sensors by brand
Flame Sensors we stock

LENNOX FLAME SENSOR/SPARK ELECTRODE

LENNOX SENSOR, FLAME

LENNOX IGNITOR / FLAME SENSOR

LENNOX FLAME SENSOR/IGNITOR KIT, DUAL ROD

LENNOX FLAME SENSOR LEAD

LENNOX WIRE LEAD, FLAME SENSOR, 59-1/2"

Flame Sensor

LENNOX ARMSTRONG DUCANE FLAME SENSOR WITH WIRE

Flame Sensor

LENNOX FLAME SENSOR

LENNOX IGNITOR AND FLAME SENSOR

LENNOX FLAME SENSOR

Flame Sensor with 64 1/2" Wire

Flame Sensor

Flame Sensor

YORK/ETC FLAME SENSOR

Flame Sensor with Cable & Clip

PILOT ASSEMBLY WITH SPARK IGNITOR AND FLAME SENSOR

Flame Sensor

FLAME SENSOR ROD LENNOX ARMSTRONG DUCANE

FLAME SENSOR ROD LENNOX ARMSTRONG DUCANE

FLAME SENSOR ROD LENNOX ARMSTRONG DUCANE

FLAME SENSOR ROD CARRIER BRYANT PAYNE DAY AND NIGHT ICP

FLAME SENSOR ROD CARRIER BRYANT PAYNE DAY AND NIGHT

FLAME SENSOR ROD GOODMAN AMANA ICP TEMPSTAR HEIL

FLAME SENSOR ROD CARRIER BRYANT PAYNE DAY AND NIGHT

FLAME SENSOR ROD LENNOX ARMSTRONG DUCANE

FLAME SENSOR ROD LENNOX ARMSTRONG DUCANE

FLAME SENSOR ROD LENNOX ARMSTRONG DUCANE

FLAME SENSOR ROD LENNOX ARMSTRONG DUCANE

FLAME SENSOR ROD YORK LUXAIRE COLEMAN EVCON

FLAME SENSOR ROD RUUD RHEEM

FLAME SENSOR ROD LENNOX ARMSTRONG DUCANE

FLAME SENSOR ROD UNIVERSAL

FLAME SENSOR ROD LENNOX ARMSTRONG DUCANE
Image coming soon
000-472
LENNOX ROD-PROP
Image coming soon
060-721
FLAME SENSOR KIT
Image coming soon
120-663
FLAME SENSOR
Image coming soon
120-668
SENSOR, FLAME L/H
Image coming soon
120-669
SENSOR, FLAME R/H
Image coming soon
120-915
SENSOR,FLAME,STRAIGHT,ULTRA LOW NOX
Image coming soon
120-944
SENSOR,FLAME,HEAT,GAS,PREMIER
Image coming soon
121-113
Flame Sensor Electrode with Bracket
Image coming soon
121-427
TEMPERATURE SENSOR,144" LEAD
Image coming soon
121-701
YORK S1-2845-3111 FLAME SENSOR
Image coming soon
121-710
SENSOR,FLAME MERCURY
Image coming soon
121-711
SENSOR,FLAME MERCURY
Image coming soon
121-712
SENSOR,FLAME MERCURY
Showing 48 of 68. Pick your brand above for the full list, or browse every part by number.
Flame Sensors questions
- Can I clean a flame sensor instead of replacing it?
- Often, yes. A flame sensor fails because a thin oxide film builds on the rod and blocks the microamp signal. Shut off power and gas, pull the rod, and polish it with fine steel wool or an emery cloth — never sandpaper, which leaves grit and scratches that foul faster. If cleaning buys you only a few weeks, the rod has thinned or the porcelain insulator is cracked, and it needs replacing.
- Why does my flame sensor keep getting dirty?
- Rapid re-fouling usually means something upstream is wrong, not that the sensor is defective. The common causes are a partly blocked burner, incorrect gas pressure, a cracked heat exchanger, or poor combustion air. If you are cleaning the rod more than once a season, have the combustion checked.
- Do I need the exact OEM flame sensor for my furnace?
- Use the sensor specified for your model. The rod length, bend, and bracket position set how deep it sits in the flame, and a sensor that looks similar but sits wrong will read a weak signal and drop out intermittently — the hardest kind of fault to chase.
Need it today in Greater Vancouver?
Call ahead and we will set the part aside at the Coquitlam counter. No account, no trade card, no minimum order.