The gas valve meters gas to the burners and is opened by the control board once the safeties have proven. It is a safety-critical component: it is the part that stops gas flowing when anything else in the chain fails. Work on gas connections carries real risk, and in British Columbia gas fitting is licensed work.
155 gas valves & regulators in stock, ready for same-day pickup at our Coquitlam warehouse or shipped worldwide.
Signs your gas valve may have failed
- Ignitor glows through its full cycle but no gas arrives
- Burners light and immediately go out
- Gas smell around the furnace — leave and call for service
- Valve receives 24V at its terminals but does not open
Not sure which part you need? Call 1-778-759-9864 with your furnace model number and we will confirm it before you order.
Shop gas valves & regulators by brand
Gas Valves & Regulators we stock

LENNOX GAS VALVE, 2 STAGE, NATURAL, 24V, 1/2"

LENNOX CONVERSION KIT, GAS VALVE, NATURAL TO PROPANE

LENNOX ORIFICE, STRAIGHT, #54, PROPANE GAS

LENNOX REVERSING VALVE

LENNOX GAS VALVE, 24 VOLT, 60HZ, NATURAL GAS, 3/4", STEP OPEN

LENNOX GAS VALVE, NATURAL, 3.2" WC, 24V, 1/2"

Gas Valve, 24 Volt, 50/60HZ, Modulating, Propane Gas

LENNOX CONTROL BOARD

LENNOX GAS VALVE, 2 STAGE, 3/4" NATURAL, 24V FAST OPEN

Thermal Expansion Valve, R410A, 4 Ton

Coil, Reversing Valve, 24 Volt, 50/60HZ

Carrier Valve Core

Gasket, Service Valve

Gas Valve, Natural, 24V

Thermal Expansion Valve Kit

Gas Valve, Natural Gas, 24 Volt, 50/60HZ, 3.2"WC, 3/4" x 1/2"

Gas Valve, Natural, 24 Volt, 3/4", White Rodgers

GOODMAN/AMANA REVERSING VALVE W/ 24V COIL

GOODMAN/AMANA 24V REVERSING VALVE COIL

GOODMAN/AMANA REVERSING VALVE

GOODMAN/AMANA COIL, REVERSING VALVE, 24V, 50/60HZ

Gas Valve, Natural, 2 Stage, 24V, Hot Surface/Direct Spark, 1/2"
Image coming soon
000-523
LENNOX VALVE SER- BRASS REFRIDGERANT
Image coming soon
020-281
VALVE,SERVICE, K COMP, 1.12 ODS X 1.75-1
Image coming soon
020-284
VALVE SOLENOID
Image coming soon
020-290
VALVE, BALL
Image coming soon
020-307
VALVE; GAS, 2 STAGE, 1/2-14 NPT, 24V, 50/60 HZ, "J" SERIES
Image coming soon
020-401
VALVE; GAS 2STAGE, 36H (LARGE 3/4)
Image coming soon
060-478
KIT REPLACEMENT TX VALVE
Image coming soon
060-790
INSULATION,GAS VALVE 60K
Image coming soon
060-791
INSULATION, GAS VALVE 90K
Image coming soon
100-351
SOLENOID VALVE
Image coming soon
100-352
1/2"X1/2" NG 200KBTU GAS VALVE
Showing 33 of 155. Pick your brand above for the full list, or browse every part by number.
Gas Valves questions
- Should a homeowner replace a gas valve?
- We sell the part to whoever needs it, but be straight with yourself about this one. Replacing a gas valve means breaking a gas connection and leak-testing it afterwards, and in BC that is licensed gas-fitter work. If you are not certain of your leak test, have a licensed technician fit it — we will supply the correct part either way.
- How do I confirm the valve is the failed part?
- Verify that 24V actually reaches the valve terminals during the trial for ignition. If the voltage is present and the valve does not open, the valve has failed. If the voltage never arrives, the fault is upstream — the board, a safety, or the flame-sense circuit.
- If I smell gas, what should I do?
- Do not troubleshoot. Leave the building, and from outside call FortisBC at 1-800-663-9911 or 911. Do not operate switches or anything that could spark on your way out.
Need it today in Greater Vancouver?